  1. Garage pedestrian door size | The Building Code Forum

    Nov 24, 2025 · I have a single car garage with a sectional overhead door, I have space on one stucco wall for a 24 x 75 pedestrian door. will that size be acceptable since it is not the main …

  2. NC Garage Legal Finish Requirement | The Building Code Forum

    Jan 29, 2024 · The garage is 100% residential- not a business. The first floor has lights & outlets, the second floor only has a preexisting light fixture (exterior light) from the original house and …

  3. S-1 & S-2 Regarding Parking Garage - The Building Code Forum

    Jan 7, 2015 · Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage". Section 311.3 Classifies "Parking garages, open …

  4. Egress Door From Garage | The Building Code Forum

    Oct 16, 2009 · My attached garage has a man door, and my detached garage has a man door. On the other hand, under the IBC an overhead garage door is allowed to be used as a …

  5. Egress through a garage. | The Building Code Forum

    Apr 9, 2015 · A detached garage is not going to require egress in the same manner as a habitable space. How do you egress out of a garage itself?

  6. Equipment Bollard in a Residential Garage - The Building Code …

    Oct 20, 2009 · Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab. We also have two alternates that are …

  7. Step from garage into House?? | The Building Code Forum

    Jul 22, 2019 · I do not see anywhere in the IRC 2015 that requires a step from the garage into the house. I saw the opening penetrations R302.5 & Garage section R309. Is the step still a …

  8. Garage Step and Slope - The Building Code Forum

    Nov 15, 2020 · Garage floor surfaces shall be of approved noncombustible material. The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the …

  9. Branch Circuit to Detached Garage - The Building Code Forum

    Oct 16, 2009 · An electrical service disconnect is located in or on the main structure. One of the panelboard has a 20A GFCI breaker that is labeled "garage." The garage is detached and the …

  10. Garage distance separation from dwelling - Section R309

    Dec 4, 2009 · Re: Garage distance separation from dwelling - Section R309 Uncle Bob, That's how I see it (I just don't believe it). I would not interpret measuring from overhang. Any other …